Part Number Hot Search : 
AT24WC PN103 20D3G 24006 L211658 MR7A5 H1343 ES3AB11
Product Description
Full Text Search
 

To Download TFS70F1 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 TFS70F1.doc
Version 2.4
09.04.2001
VI TELEFILTER
Filter Specification
TFS 70 F1
1/5
1.
Measurement condition :
25 C 0 dBm. for input: for output:
Ambient temperature TA: Input power level: Terminating impedances at fc:
56 -30 pF. 56 -30 pF.
2. Characteristics :
Remark: Reference level for the relative attenuation arel of the TFD 70F1 is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The reference frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating temperature range is not included in the production tolerance scheme.
Data Insertion loss (Reference level) ae
typ. value 22,5 dB 70 MHz
tolerance / limit max. 25 dB
Reference frequency fc at ambient temperature (fCTA) Pass band ( PB ) at ambient temperature TA: Amplitude ripple in PB (p-p): Bandwidth at ambient temperature : 1 dB - band width 3 dB - band width 40 dB - band width 45 dB - band width 50 dB - band width Relative attenuation fc ..... fc 6,1 MHz fc 6,65 MHz fc 6,8 MHz fc 7,2 MHz fc 8 MHz fc 10,2 MHz fc 18,2 MHz fc fc fc fc fc fc fc fc 6,1 6,2 6,8 7,2 8 10,2 18,2 35 arel MHz MHz MHz*) MHz*) MHz MHz MHz*) MHz
70 0,10MHz fC - 6,1 MHz .... fC + 6,1 MHz
0,5 dB 12,24 12,45 13,23 13,30 13,32 45 48 52 55 45 45 4,1 100 7,5 52 4 / 3,5 65 dB dB dB dB dB dB s ns (p-p) dB dB dB MHz MHz MHz MHz MHz
max. 1,0dB min. min. max. 12,2 MHz 12,4 MHz 13,3 MHz
max. max. min. min. min. min. min. min.
1 3 40 45 48 50 40 40
dB dB dB dB dB dB dB dB
Group delay ( mean value in PB ) Group delay ripple (p-p): fc ... fc 6 MHz Deviation from linear phase (p-p): fc ... fc 6 MHz Triple transit attenuation compared to main signal Input/Output return loss with matching network (S11/S22): Crosstalk Substrate material Temperature coefficient of frequency ( Tcf ) Frequency deviation of fc over temperature Operating temperature range Storage temperature range
max. 4,5 s max. 200 ns
LiNbO3 -86 ppm/K -94 ppm/K fc(Hz) = Tcf(ppm/K) x (T - TA) x fCTA (MHz) - 25 C ... + 80 C - 40 C ... + 85 C
*) in this frequency range the limit line is of type SLOPING LINE
Generated:
Dunzow W.P.
Checked/Approved:
Dr. Bert Wall
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 Email: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS70F1.doc
Version 2.4
09.04.2001
VI TELEFILTER
Filter Specification
TFS 70 F1
2/5
3. Package :
35 Max
20,5 Max
TFS tft
70F1 N08
Datecode: L M N ....
Year+week 1999 2000 2001 ........
5,5 5,5
1 15,24 24
12
13
Pin 23 Input Pin 24 Input RF return Pin 11 Output Pin 12 Output RF return Pin 4-9, 16-21 Package ground Pin 1-3, 10, 13-15, 22 Dummy
2,54
11x2,54 = 27,94
4. 50 matching network:
1 11 12
L2 L1
24 23
13
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 Email: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS70F1.doc
Version 2.4
09.04.2001
VI TELEFILTER
Filter Specification
TFS 70 F1
3/5
5. Stability characteristics :
After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 25 C to 55C / 95% r.H. / 10 cycles DIN IEC 68 - 2 - 30 Db
2. Vibration:
3. Damp heat: (cycle) 4. Resistance to solder heat (reflow):
max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 Email: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS70F1.doc
Version 2.4
09.04.2001
VI TELEFILTER
Filter Specification
TFS 70 F1
4/5
6. Air reflow temperature conditions :
1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods main-heating periods 150 C - 170 C over 200 C 60 sec. - 90 sec. 20 sec. - 25 sec. peak temperature 255 C 5 C
Air reflow profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240
Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C
time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 Email: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS70F1.doc
Version 2.4
09.04.2001
VI TELEFILTER
7. History :
Version 2.4 Reason of Changes
Filter Specification
TFS 70 F1
5/5
Name Dunzow W.
Date 09.04.2001
Generate filter specification in actually format. - change package; - add " 5. Sability characteristics ";
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 Email: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.